Prekių katalogas

  • Srovės matavimo replės TRUE RMS AC/DC 10MA - 1000A

    Kodas: YT-730933
    4855 
    Šią prekę turime sandėlyje.
    Į krepšelį 
    Skaičiuojama...
    i

    Profesionali įrankių linija

    Prekės ženklas
    YATO
  • TRUE RMS AC/DC CLAMP METER 10MA - 1000A

    Alternating voltage measurement
    0-750 V a.c.
    Direct voltage measurement
    0-1000 V d.c.
    AC
    0-1000 A
    DC
    0-1000 A
    Resistance measurement
    0-60 MΩ
    Capacitance measurement
    0-100 mF
    Frequency measurement
    0-10 MHz
    Temperature measurement
    -30 ~ +1000 ˚C
    Continuity test
    0-50 Ω
    Conduction test
    yes
    Diode test
    YES
    Battery test
    yes
    Peak value recording
    yes
    Non-contact AC voltage detection NCV
    yes
    Dimensions
    194x75x35 mm
    Material
    ABS
    Max. clamp opening
    25 mm
    Max. wire diameter for measurement with clamp
    25 mm
    Display type
    LCD
    Display range
    6000
    LED backlight
    YES
    Audible signal
    yes
    Auto range measurement
    yes
    Automatic power off
    15 min
    Data Hold
    yes
    Sampling rate
    3 times per second
    TRUE RMS
    yes
    Flashlight function
    YES
    Battery power supply
    Battery type
    3x1.5V; AAA
    Low battery indicator
    yes
    Operating temperature range
    0~40 ˚C
    Relative working humidity Rh
    < 75 %
    Storage temperature
    -10 ~ +50 ˚C
    Weight
    0.2 kg
    Application
    electrical

    Universal clamp meter with TRUE RMS function, with automatic and manual range. It allows to perform basic and advanced measurements of electrical quantities. Using the measuring clamps, you can measure both direct and alternating current in the range from 10 mA to 1000 A. The measurement is performed without the need to disconnect the circuit or disconnect it from the power source. The meter allows you to measure significantly higher current than conventional electrical meters. The test probe leads have silicone, flexible and high-temperature resistant insulation.

    Basic measurements:

    AC voltage measurement: A.C. 0-750 V, TRUE RMS (40-1000 Hz)
    DC voltage measurement: D.C. 0-1000 V
    AC current measurement: A.C. 0-1000 A, TRUE RMS (40-1000 Hz)
    DC current measurement: D.C. 0-1000 A
    resistance measurement: 0-60 MΩ
    diode test: IF 2 mA, UR 3.2 V
    continuity test: 0-50 Ω
    Additional measurements:

    capacitor capacitance measurement: 0-100 mF
    frequency measurement: 0-10 Mhz
    temperature measurement: -30 to 1000 °C
    non-contact AC voltage detection: NCV
    inrush current measurement
    phase presence measurement (probe function)
    Measurement accuracy:

    Example of determining accuracy for AC current measurement. Calculations for measurement result: 30 A

    measurement accuracy of the YT-730933 meter for this range is: ±(2.5%+10), resolution 0.01 A
    measurement error calculation formula: (measurement result x 2%) + 30 x resolution
    calculations: (30 x 2.5%) + 10 x 0.01 = 0.75 + 0.1 = 0.85 A
    Actual result taking into account the measurement error for the 30 A indication = 30 ± 0.85 A.

    result taking into account the measurement error for the AC voltage measurement indication: 235 V = 235 ± 2.85 V
    result taking into account the measurement error for the DC voltage measurement indication: 12 V = 12 ± 0.146 V
    The table with the resolution and accuracy for a given measurement can be found in the user manual.

    Built-in functions:

    TRUE RMS - a meter with this function displays the true effective value of the alternating voltage or current. Unlike averaging meters, devices with TRUE RMS display the correct value not only for a sinusoidal waveform, but also for distorted sinusoidal waveforms, e.g. higher harmonics, or square or triangular waveforms. A mandatory function wherever there are switching power supplies, motor inverter drives, HVAC installations, etc. in the circuit.
    NCV - non-contact detection of alternating voltage using the inductive method. The meter detects the presence of voltage in an insulated wire, it can also indicate the phase wire.
    LINE - contact detection of alternating voltage, works like a traditional tester. After inserting the measuring probe into the hole in the socket, in the case of the presence of a phase, four lines will appear on the display, the signal diode will light up and an intermittent sound signal will be emitted.
    AUTO - automatic adjustment of the measurement range. When measuring unknown values ​​using a meter with manual range adjustment using the knob, measurements should be taken successively from the largest range to the most accurate. Otherwise, we risk damaging the device. However, in the case of a multimeter with the AUTO function, it is enough to take one measurement and the meter will automatically find the optimal range. The meter starts in AUTO mode by default.
    RAN - manual change of the measurement range
    DATA HOLD - saving the currently measured value on the display
    INR - measurement of the starting current using measuring clamps. The meter will measure the starting current 80 ms after starting the device.
    Additional information:LCD display, maximum displayed result: 6000
    backlighting of the screen and the clamp measuring field
    sound signal in the continuity test for resistance below 50Ω
    clamps open to 25 mm
    measuring probes 14 cm long
    length of the cable with probes: 103 cm
    diameter of the cable with insulation: 3.6 mm
    cover included
    design with overload protection
    automatic shutdown of the meter after 15 minutes of inactivity
    possibility of turning off the automatic shutdown mode of the device
    low battery indicator
    power supply: three 1.5 V (AAA) batteries
    Note!

    Current intensity measurement using clamp meters is performed only and exclusively on a single core, a single wire. Fastening the clamps to a multi-core cable without isolating a single core will show an incorrect result or zero current flow