Prekių katalogas

  • Srovės matavimo replės automatinės AC/DC 600A

    Kodas: YT-73093
    4775 
    Šią prekę turime sandėlyje.
    Į krepšelį 
    Skaičiuojama...
    i

    Profesionalių įrankių linija.

    Prekės ženklas
    YATO
  • TRUE RMS CLAMP GAUGE WITH AUTOMATIC RANGE AC / DC 600A
    Automatic range: Yes
    Frequency measurement: 0-10MHz
    AC voltage measurement: 0-600V + True RMS
    DC voltage measurement: 0-600V
    Capacitance measurement: 0-60mF
    Resistance measurement: 0-60MΩ
    Temperature measurement: -30 to 1000 ° C
    Alternating Current: 0-600A + True RMS
    Constant Current: 0-600A
    Continuity test: YES
    Diode test: YES
    Product description
    The universal clamp meter YT-73093 with an automatic range for each measurement enables basic and advanced measurements of electrical quantities. The meter is equipped with measuring clamps that allow you to measure the intensity of direct and alternating current in a single conductor using the built-in HALL sensor. The measurement takes place without the need to disconnect the circuit or disconnect it from the power source, and allows you to measure a much higher current than with conventional electric meters.

    BASIC MEASUREMENTS

    AC voltage measurement: A.C. 0-600V, TRUE RMS
    DC voltage measurement: D.C. 0-600V
    AC current measurement: A.C. 0-600A, TRUE RMS
    direct current measurement: D.C. 0-600A
    resistance measurement: 0-60MΩ
    diode test: IF 5mA, UR 3V
    continuity test: 0-50Ω
    ADDITIONAL MEASUREMENTS
    capacitor capacity measurement: 0-60mF
    frequency measurement: 0-10Mhz
    temperature measurement: -30 to 1000 ° C
    non-contact detection of alternating voltage: NCV
    MEASUREMENT ACCURACY

    An example of determining the accuracy for the measurement of AC current. Calculation for the measurement result: 30A

    The accuracy of the measurement of the YT-73093 meter for this range is: ± (2.0% + 30), resolution 0.01A
    calculation of measurement error formula: (measurement result x 2%) + 30 x resolution
    calculation: (30 x 2%) + 30 x 0.01 = 0.6 + 0.3 = 0.90A
    The actual result with the measurement error for the indication 30A = 30 ± 0.90A.

    the result taking into account the measurement error for the AC voltage measurement indication: 235V = 235 ± 4.175V
    result taking into account the measurement error for the DC voltage measurement indication: 12V = 12 ± 0.09V
    The table with the resolution and accuracy for a given measurement can be found in the user manual.

    BUILT-IN FUNCTIONS

    TRUE RMS - a meter with this function calculates the real effective value of AC voltage and current for both sinusoidal and non-sinusoidal waveforms. The device first measures the real value of the sine wave in several time intervals → then squares the measurement results → sums them up → calculates the mean → and finally the mean result takes the square root. The measurement result is a real RMS voltage / current, even for a deformed sinusoid or square wave.
    NCV - non-contact detection of alternating voltage with the induction method. The meter detects the presence of voltage in an insulated conductor, it can also indicate the phase conductor
    AUTO - automatic adjustment of the measuring range. If you measure unknown values ​​with a handwheel manual ranging, take measurements sequentially from the largest range up to the range giving the most accurate result - otherwise you risk damaging the device. However, in the case of a multimeter with the AUTO function, it is enough to take one measurement and the meter will automatically find the optimal range. By default, the meter starts in the AUTO mode
    DATA HOLD - saving the currently measured value on the display
    PEAK HOLD - keeping the highest measured value on the display by means of measuring probes
    INRUSH current - measurement of the inrush current using measuring clamps. The meter will measure the current within 100ms from starting the device
    ADDITIONAL INFORMATION

    LCD display, the maximum displayed result: 6000
    backlight of the screen and the clamp measurement field
    automatic switching of the diode test on the continuity test with circuit resistance below 50 Ω (no possibility to set the meter for diode test only)
    acoustic signal in the circuit continuity test for resistance below 50 Ω
    The clamp opens up to 25 mm and enables the measurement of a single conductor with a maximum diameter of 25 mm
    measuring probes 14.5 cm long
    cable length with probes: 97 cm
    wire diameter with insulation: 3.5 mm
    a cover is included in the set
    construction with overload protection
    automatic shutdown of the meter after 15 minutes of inactivity
    the ability to disable the automatic shutdown mode of the device
    low battery indicator
    power supply: two 1.5V (AAA) batteries

    Current measurement with clamp meters is performed only on a single conductor, a single conductor. Clamping the clamp on a multi-core cable without isolating a single core will show an incorrect result or zero current flow.

    Parameters
    Auto range: YES
    Frequency measurement: 0-10Mhz
    AC voltage measurement: 0-600V + True RMS
    DC voltage measurement: 0-600V
    Capacitance measurement: 0-60mF
    Resistance measurement: 0-60MΩ
    Temperature measurement: -30 to 1000 ° C
    Alternating Current: 0-600A + True RMS
    Constant Current: 0-600A
    Continuity test: YES
    Diode test: YES